Recent content by cdug619

Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum

Help Support Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. cdug619

    Spring 2024 Corny Keg Giveaway

    Most recent was a West Coast IPA with Cascade, Amarillo and Centennial. Thanks for the giveaway!
  2. cdug619

    BruControl: Brewery control & automation software

    Started up the software and it successfully verified for me. I am on Professional as well.
  3. cdug619

    BruControl: Brewery control & automation software

    Thanks! The goal was to just set and view the status of the HLT via globals. Thanks for the tips on the timer. Script was still a work in progress but good to know. I like the different colors on the switch as well!
  4. cdug619

    BruControl: Brewery control & automation software

    It appears that the sleep 1000 was the culprit. I added another half second and the original script works. I also messed with the Calc Time and the Out Time on the element but those didnt seem to make a different.
  5. cdug619

    BruControl: Brewery control & automation software

    Script is below. I got it working. Most likely it was due to how I wrote it. :) I ended up adding another if and it works fine now. [loop] "ele_HLT" Target = "glo_HLTTarget" Value if "sw_Strike" state == false stop "tmr_Timer" wait "sw_Strike" state == true reset "tmr_Timer"...
  6. cdug619

    BruControl: Brewery control & automation software

    Correct. If just controlling it via the element control settings with a temp probe plugged in, it works as expected. If the temp is 68 and I set it for 69, I see about 30% power. If I up it to 90, it goes to 100% power. If I try to do target changes via a script and a global, the target...
  7. cdug619

    BruControl: Brewery control & automation software

    ok one more :) Trying to set up a PWM PID for controlling my HLT. When updating the target in the device box, the Output (have converted to %) updates correctly. When I have a global in a script setting the target, the target updates correctly as well as temp if I hold the probe but the...
  8. cdug619

    BruControl: Brewery control & automation software

    Thanks! I think I will revise my screen to do just that. Use that same timer and repurpose it for each step....especially now that I know I can change the display name if I want to.
  9. cdug619

    BruControl: Brewery control & automation software

    Global Timers Tried searching and could not find the answer. (still very new to scripting) My goal is to have a cluster of hop addition countdowns that all start when I start the boil process. I'm able to create a timer and set the time and display name via a script no prob but while...
  10. cdug619

    BruControl: Brewery control & automation software

    Was the ESP32-S3 firmware ever released?
  11. cdug619

    Summer 2023 Corny Keg "Giveaway

    6 to 8 depending on if I have used the same bottle for closed transfers
  12. cdug619

    Glycol Chiller Doesn't Cool Below 43F/6C

    Give it a good shake and see if the temp drops. I thought the same thing on my set up. I've noticed quite a bit of temperature stratification during cold crashing when the wort isn't moving from fermentation. I have a chronical and with a Tilt floating at the top, the SS probe in the probe...
  13. cdug619

    Clogged dip tube - I think

    When hooking the gas to the liquid out, did you pull the pressure release? Guessing you did some of these but for the sake of mentioning... If tank is purged, do you hear gas going in when on gas in side? if tank is purged, do you hear bubbles when hooking up gas to the liquid side? and what...
  14. cdug619

    Herms setup positioning temperature sensor

    In my 3 vessel system, I have one probe in the HLT, one coming off the HERMS coil on its way to the mash tun and one at the out of the mash tun going to the HERMS. Using one pump for mash circulation, obviously :), and one for the HLT to keep the temp consistent within the vessel. This past...
Back
Top