Search results

Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum

Help Support Homebrew Talk - Beer, Wine, Mead, & Cider Brewing Discussion Forum:

This site may earn a commission from merchant affiliate links, including eBay, Amazon, and others.
  1. Piggles22

    BruControl: Brewery control & automation software

    Hopefully this forum is still active. It’s been awhile since I last checked. I’m in the process of upgrading my computer and need to transfer my BC activation. I’ve downloaded the latest version of BC and when I enter my activation email I get a message telling me to deactivate it my other...
  2. Piggles22

    Saison Advise

    I really like the Belle Saison yeast for the style. It has high a high tolerance for fermentation temps (up to 35º C / 95º F according to the Lallemend specs) and can actually benefit flavor-wise from higher than 'normal' fermentation temps (IMO it tends to bring out more of the pepper and clove...
  3. Piggles22

    BruControl: Brewery control & automation software

    Unfortunately I did not grab a screen shot of that at the same time. Next time...
  4. Piggles22

    BruControl: Brewery control & automation software

    PID Tuning: Below is a graph of my PID output simply trying to maintain a constant temperature at my MT recirc line. I'm using the default suggested settings (Kp = 30 / Ki =1 / Kd = 5). Just wondering if this is a normal output or if the curve can be smoothed out for tighter control. I get about...
  5. Piggles22

    Kettle Port Configuration

    With an electric kettle (HLT or BK) and a RTD (or other type) temperature sensor, is it okay to locate the temperature sensor directly above the heating element (about 4" above) or should these be offset by a number of degrees around the circumference of the kettle? (Assuming the heating element...
  6. Piggles22

    BruControl: Brewery control & automation software

    Thanks for confirming; another one for the "fix it" list.....
  7. Piggles22

    BruControl: Brewery control & automation software

    Sorry, it was a little out of context. I was trying to get a "message" to blink on and off in the workspace by looping and I mistakenly tried to assign a value to a sleep command (sleep = 1000). The script stalled and did not give an error message as to why, but it also shows that the script is...
  8. Piggles22

    BruControl: Brewery control & automation software

    An obvious typo but no error message as to the problem...script is still running(?) but not flashing the " message".
  9. Piggles22

    BruControl: Brewery control & automation software

    A couple basic questions about scripts: Is it possible to have BC start up with no scripts running, then use a device element (i.e. a button on the workspace) to start a brewing script? Can BC be configured to open with the script window always closed by default and the workspace locked by...
  10. Piggles22

    BruControl: Brewery control & automation software

    Looks like this works: "element name" UserControl = false
  11. Piggles22

    BruControl: Brewery control & automation software

    Can the User Control property of an element (and global element) be enable and disabled with a script command? If so, what is the script command and syntax?
  12. Piggles22

    BruControl: Brewery control & automation software

    I think I may have my SSR's connected to the wrong port on the MEGA. I have standard SSR's connected to ports 42 and 43 using PID elements in BC. According to this I should have my standard SSR's connected to ports 44 & 45. I just want to be sure I'm reading this right.
  13. Piggles22

    Passivation - fill the entire kettle?

    Any thoughts on recirculating citric acid through a stainless steel plate chiller?
  14. Piggles22

    BruControl: Brewery control & automation software

    I'm trying to change the onscreen display name of a button. The script runs fine and updates the Value Appearance field in the Properties window but does not update the name on the workspace...is this related to the same? [name] new string name name = OFF GO DisplayName = name sleep 1000 name...
  15. Piggles22

    BruControl: Brewery control & automation software

    A graphics bug...? You may already be aware of this... Tried to change the appearance properties of a Button but it had no effect. I tried to apply the LED type to the Proceed button and change the On / Off colors to Green and Yellow but button in the workspace did not change after clicking on...
  16. Piggles22

    BruControl: Brewery control & automation software

    Okay, found it! Another Novice bungle; I had a created a new STRING in the script called HTRSEL. I was looking for a device element in the workspace. Thanks for all your patience and help; you're a real Saint.
  17. Piggles22

    BruControl: Brewery control & automation software

    Screen shots with element named "HTRSEL" Screen shots with element named changed to "HTRSW". I added the "wait" statement in order to capture the screen shot.
  18. Piggles22

    BruControl: Brewery control & automation software

    Another odd find... I was making a few changes in my script and shortening the names of some of my output device elements. I have an output device which I shortened the name from "HEATER SELECT" to "HTRSEL" and changed the references to it in the script. When I ran the script I got a message...
Back