  1. T

    pH meter storage solution drying out and turning white?

    i have the same problem. I fill the cap (no sponge in it) and within 2 weeks I go check it's bone dry and white. What a poor design
  2. T

    Cleaning technique: SS Brewtech Chronical w/ chiller attached?

    I was planning on doing this same thing..My concern however is using the sump pump to run through the cleaning cycle with PBW and Hot Water and then later using the same pump to pump Starsan into the conical to sanitize. Don't we run the risk that some crud or bacteria in the pump housing could...
  3. T

    Help me with finaly making a Granville Island winter ale Clone , any help is good.

    Did you make this recipe? Anxious to know how it turned out. Also can you not just use the vodka to sanitize the cocoa and vanilla and then throw the cocoa and vanilla into secondary vs adding the vodka? Soak for maybe a few hours to just sanitze? Thx
  4. T

    Chiller Manifold for deiverting flows

    Has anyone seen a good design for being able to change flow patterns easily with valves. I want to use PEX and valves to basicallly change the direction the glycol goes through the coil on the fermenter. On the fermenter is 2 openings to the coil and depending which end the liquid enters, it...
  5. T

    New Spike CF10 - Temp Control

    Well I managed to stabilize the temps +/1 0.5 Deg F.. What it seems is that while to chill to 38F, you want a glycol of 28F (10F colder), when we're dealing with temps around 65 to 70 a 10F is too much. What happens is the glycol cools it down to the set temp and the pump stops but that cold...
  6. T

    Conical Cooling Conundrum (Spike CF10)

    I suppose a valve after the pump and before the conical to slow down the rate would work
  7. T

    New Spike CF10 - Temp Control

    Hi folks, I am doing my first brew in my new CF10 with heating/cooling and jacket.. I am currently doing a NEIPA and have the conical set for 69F. The Spike temp control has a preset 5 deg F differential before it kicks in heat/cool.. I occasionally go down to the basement to check on it and...
  8. T

    Conical Cooling Conundrum (Spike CF10)

    Ambient temps in basement are around 70 F. I have the complete T100 pkg from spike which includes the jacket and it is on. The chiller is made from a 5000 BTU AC. I have 2 gallons of Glycol and 6 gallons of water in an insulated cooler. It gets down to 28F no problem and I have it for 1 Deg...
  9. T

    Conical Cooling Conundrum (Spike CF10)

    Hi folks wondering if you all figured out the problem. I have my glycol at 26F and cannot get my CF10 below 44. Have 8 gallons in the conical doing a test run.. coils are not frozen and pump is running. Any ideas?
  10. T

    Spike CF10 - Questions

    Hey folks, I need to pop off my chilling lines on the T100 bundle of of the stainless chiller and reverse them..Must have them backwards. How do they pop off? What's the trick to have the quick 90 disconnect pop off thx
  11. T

    Spike CF10 - Questions

    Built my base. What an improvement
  12. T

    Spike CF10 - Questions

    Indeed! Funny I tried a few times and looked like they only went so far. As for the base, I had the exact same idea. Was going to build a 30x30 base with casters and remove the casters from the legs and then mount the unit on the new base with bolts that thread up through the base into the...
  13. T

    Spike CF10 - Questions

    Yes, I knew that they are open when positioned in parallel with the port. Was just curious to orientation. I just assembled it all, my intent with the 90 elbow is really only to put it on when I clean the unit. I plan on CIP ball in the top and open down at the bottom dumping into a bucket...
  14. T

    Spike CF10 - Questions

    I just got my new shiny CF10. Excited about it. I do have some questions. 1. Notice my valve on the transfer port. Most pics I see have them sittingg horizontal with the lever to the right and I assume you pull it forward to open. In my case the only way to get it on so I open by pulling...
  15. T

    New EZBoil Controller - Help

    I think I found my answer. https://www.homebrewtalk.com/forum/threads/do-ssrs-leak-voltage-on-the-high-side-with-no-input-on-low-side.492622/ In fact if I plug in the element, the LED does not light until the EXBoil turns it on. Interesting piece of info. I could add a resister to the...
  16. T

    New EZBoil Controller - Help

    It is in fact parallel. Does not look like it in the drawing the way I drew it but if you move the red wire connected to the LED from the conctactor to the receptacle its all connected in parallel.
  17. T

    New EZBoil Controller - Help

    Mash Mode. It should be on or off. Boil mode does a percentage of time on/off as I understand it but Mash Mode should not unless I am wrong. thx
  18. T

    New EZBoil Controller - Help

    Hi folks I finally got around to building my controller. Everything seems to be working (have not plugged in heating element) as far as tests go on voltage readings except for my 220V. My design uses a contactor which basically is controlled by a switch so that the 220V can be shut down with...
  19. T

    RTD PT100 3 Wire - How to hook it up

    Thanks for the responses. I think I am in sync with you and will not connect ground. Regards
  20. T

    RTD PT100 3 Wire - How to hook it up

    By process of deduction, I concluded the following. THere is 100 OHMs between Blue and Red and 0 OHMS between Blue(s). Therefore the Blues must go to pins 3 and 4 on EZBOIL. And Red on pin 5. Now for the ground on XLR CONN, the only thing I can think of is to attach a wire to the...